Use this form in order to communicate Service findings.
Hidden
Date
MM slash DD slash YYYY
Hidden
Time
:
Hours
Minutes
AM
PM
AM/PM
Outside Temperature
*
Please enter a number from
32
to
150
.
Weather Condition
*
Clear
Cloudy
Overcast
Partly Cloudy
Rain
Lot #
Member Name
First
Last
Inspection Address
Street Address
Address Line 2
City
CA
Alabama
Alaska
American Samoa
Arizona
Arkansas
California
Colorado
Connecticut
Delaware
District of Columbia
Florida
Georgia
Guam
Hawaii
Idaho
Illinois
Indiana
Iowa
Kansas
Kentucky
Louisiana
Maine
Maryland
Massachusetts
Michigan
Minnesota
Mississippi
Missouri
Montana
Nebraska
Nevada
New Hampshire
New Jersey
New Mexico
New York
North Carolina
North Dakota
Northern Mariana Islands
Ohio
Oklahoma
Oregon
Pennsylvania
Puerto Rico
Rhode Island
South Carolina
South Dakota
Tennessee
Texas
Utah
U.S. Virgin Islands
Vermont
Virginia
Washington
West Virginia
Wisconsin
Wyoming
Armed Forces Americas
Armed Forces Europe
Armed Forces Pacific
State
ZIP Code
Inspector Name
*
First
Is the system Operational?
*
YES
NO
PARTIAL
Contract Type
*
Owned
Lease/PPA
Unknown
Installation Type
*
Roof
Ground
Combination
# of Stories
ONE
TWO
THREE
GROUND
Main Electrical Connection
MSP & Utility Meter Location
*
ie. East side of the home or pedestal
MSP Bus Rating
*
From Label if present. If label is not present, please input "N/A"
MSP Main Breaker Rating
*
Tie-in Breaker Rating
*
Tie-in (PV) Breaker Type
Single Pole (120)
Double Pole (240)
Signs and labels are permanent and constructed of durable materials that withstand all outdoor environmental conditions and have legible lettering with clear contrasting colors. NEC 690.31(E)(4)
YES
NO
PARTIAL
The required Warning Label(s) are installed at the Sub Panel/Main Service Panel NEC 705.12(D)(4), 690.14(C)(2), 690.54, 690.56(B)
YES
NO
PARTIAL
The required Warning Label(s) are installed at the Inverter? NEC 690.35(F) for ungrounded systems NEC 690.5(C) for grounded systems
YES
NO
PARTIAL
Required Warning Label(s) are installed at the DC Disconnects/Combiner boxes NEC 690.53, 690.14(C)(2), NEC 690.35(F) for ungrounded systems, NEC 690.17(4) for grounded systems
YES
NO
PARTIAL
Required Warning Label(s) are installed at the AC Disconnect. NEC 690.14(C)(2), 690.54, 690.56(B), 705.12(D)(4) when fused or line side tap
YES
NO
PARTIAL
N/A
Describe System Grounding at POC
*
ie. The equipment-grounding conductor (EGC) is continuous to all metal components and connected to the main grounding electrode conductor per NEC 250, 690 Section V.
Additional Information
*
Visible Concerns
*
Inverter
Inverter Architecture
*
String
Micro
Hybrid
None Present
Number of Inverters
*
If Micro Inverter, please return to this section once on the roof.
Inverter(s) Location(s)
*
Inverter Operational?
*
YES
NO
PARTIAL
Inverter manufacturer
*
Inverter Model(s)
*
If Micro inverters, please return to this section once on the roof.
Inverter(s) SN(s)
*
If Micro inverters, please disregard
Inverter Listed UL1741?
YES
NO
N/A
Number of Strings to inverter
String(s) DC Voltage measured at the inverter or combiner
AC Output Voltage measured at the inverter or combiner
Min 36" clearance required around equipment per NEC 110.36(A)?
YES
NO
Is the inverter in Direct Sunlight?
YES
NO
Is a DC disconnect present?
YES
NO
BUILT-IN
Is an AC Disconnect present?
YES
NO
Is the AC Disconnect within 10 Feet of Inverter
*
YES
NO
AC Disconnect Size
(Amps) From label
Monitoring System Installed?
YES
NO
Describe System Grounding at Inverter
*
ie. The equipment-grounding conductor (EGC) is continuous to all metal components and connected to the main grounding electrode conductor per NEC 250, 690 Section V.
Battery Information(if any)
System Wiring
Is ground-level conduit property secured
YES
NO
Standard building wire conductors and appropriate wiring methods utilized per NEC 690, 110.14(A)
YES
NO
Conductors are clearly marked. Grounded conductors are marked white or gray and equipment grounding conductors (EGC) shall be green, green/ yellow, or bare. NEC 200.6, 250.119, 310.110
YES
NO
Any signs of damaged or improper wiring?
YES
NO
Additional Wiring Recomendations
Roof/Ground Overview
Roof Material
Ground Mount
Composition Shingle
Concrete Tile
Clay Tile
Flat torch-down
Tar& Gravel
Metal Roof
Wood Shake
Roof/Ground conductors properly sized and rated for 90 degrees C
YES
NO
Nonmetallic-sheathed conductors and cables secured within 12 inches of each box, cabinet, conduit body or other termination NEC 334
YES
NO
Conduit rated for location with supports properly spaced for size and type of conduit NEC 358, NEC 352, 350.22
YES
NO
Minimum bending radius of the USE-2 cable or PV Wire is no more than 5x the diameter of the cable NEC 334.24
YES
NO
All PV Source Circuit free-air conductors have 90 degree C, sunlight, and wet service ratings. Single-conductor cable type USE-2 and listed and labeled as PV wire permitted in PV source circuits NEC 690.31(B)
YES
NO
Strain relief fitting used at the junction box or the transition into conduit
YES
NO
DC PV source circuits run inside the building and they are in metal conduit from the point of penetration into the building to the first accessible disconnect NEC 690.31(E)
YES
NO
Roof Condition
Number of Modules on Site
*
Module Type
*
Manufacturer and Model Number
Module nameplate Rating (W)
Any Visible Module Damage?
*
NO
YES
Module UL1730 Rating
YES
NO
PV modules are properly grounded with lugs on each panel or approved equivalent grounding method is used
YES
NO
Rapid Shutdown Installed?
YES
NO
RSD Type
Number of Arrays
*
Array Azimuth(s)
Support with photo
Array Tilt
Support with photo
Array Shading
NONE
SOME
LOTS
Type of Racking Installed
Racking Condition
Racking installed level and properly secured?
YES
NO
Modules passed hand lift test?
YES
NO
All components are properly tightened.
Distance from roof to lowest point of array
*
Support with photo
Junction Boxes Installed
YES
NO
Junction box(s) rated for exterior application (NEMA certified)
YES
NO
Junction box(s) securely installed
YES
NO
Required Warning Label(s) used at the Junction Box. NEC 690.31(E)(3), NEC 690.35(F) for ungrounded systems, NEC 690.17(4) for grounded systems
YES
NO
Micro Inverters, Optimizers and RSD Properly secured to modules or rail
*
YES
NO
N/A
Conduit supports rated for the installation and properly installed
*
YES
NO
N/A
Has proper wire management been excercised?
*
YES
NO
Any alterations made to the modules?
*
NO
YES
ie. drilling module frames
Conduit penetrations properly sealed
YES
NO
Is conduit properly secured
YES
NO
N/A
Additional Notes and Recommendations